Ambient Conditions (all models)

Navigation:  Hardware Specification >

Ambient Conditions (all models)

Previous pageReturn to chapter overviewNext page

Temperature

0 - 40 °C

Relative humidity (non-condensing)

20 - 80%

Note: The above limits apply to operation and storage of the camera.

Calibration Stability

Temperature changes inevitably cause slight deformations of the camera housing and its internal components. The approximate measurement deviations under temperature changes is quantified as follows:
 

Relative Z-coordinate deviation
(varies with operating distance)
 

≤ 5e-5 / °C at 1400mm distance
≤ 2.5e-5 / °C at 300mm distance

Angular X deviation
 

≤ 2e-5 rad / °C

Angular Y deviation
 

≤ 5e-5 rad / °C

 
Example

Let's assume you are operating your camera at approximately 300mm distance. The deviations you should expect under an ambient temperature change of 10°C are approximately:
 

Z-deviation: ≤ 2.5e-5/°C * 300mm * 10°C = 0.075mm

X-deviation: ≤ 300mm * tan(2e-5/°C * 10°C) = 0.075mm

Y-deviation: ≤ 300mm * tan(5e-5/°C * 10°C) = 0.150mm