InlierThreshold

Navigation:  NxLib API > Commands > FitPrimitive > Parameters >

InlierThreshold

Previous pageReturn to chapter overviewNext page

Specifies the threshold in millimeters to judge if a point is an inlier. If a point is closer to the primitive than this threshold it is considered to lie on the surface of the primitive. See also FitPrimitive.for a description how this parameter influences the search algorithm.

Format

Number

The inlier threshold in millimeters.

Note: This parameter can also be specified separately for each primitive by inserting it into a search parameter set, e.g. as subnode under Primitive/\0.