Setting Up a Stereo System with an X30/X36 Projector

<< Click to Display Table of Contents >>

Navigation:  Introduction >

Setting Up a Stereo System with an X30/X36 Projector

Note: Please also read the Eye Safety topic before operating an X-Series projection module.

When your X-series projector was delivered without sensors you have to perform the following steps to set it up:

Attach goniometers and extension profiles to projection module

owithout baseline extenders:

x-200-exploded-1

owith baseline extensions:

x-400-exploded-1

Mount uEye cameras on goniometers

owithout baseline extenders:

x-200-exploded-2

owith baseline extensions:

x-400-exploded-2

Connect GigE and synchronization cables on 'Camera 1' and 'Camera 2' GigE and GPIO ports

Connect GigE and power supply cables to 'External' GPIO port of projection module

Open NxView.

Create a stereo camera by pairing the projector with the corresponding sensors.

oSelect your projector and click on "Pair..." to open the pairing dialog.

oSelect the cameras that will become the left and right sensor of the stereo camera. Make sure that the trigger cables are connected to the projector.

Calibrate the stereo camera.

oSelect the stereo camera that was just created and click on "Calibrate...".

oFollow the instructions of the calibration wizard.

You camera is now ready and can be opened in NxView.