All calibration targets of outer size 160x160mm and smaller are screen printed ceramic substrates of nominal thickness 1mm. Larger calibration targets consist of aluminum composite material of 3mm thickness. For all types the printing process is conducted with high-precision screens at room temperature without per-piece print calibrations or measurements. We therefore cannot provide any hard guarantees on the accuracy, but the following sections will outline what printing accuracy can be expected in general.
The position of the print is not aligned to the substrate.
•Accuracy of barycenters of dot grid
oRelative deviation of distances of neighboring points: ≤ 0.1e-3
oAbsolute deviation of grid spacing: ≤ 1e-3
•Thermal expansion: ~ 8e-6/K
•Outer dimension tolerance: ±0.25mm
•Thickness tolerance: ±0.1mm
•Accuracy of barycenters of dot grid
oRelative deviation of distances of neighboring points: ≤ 0.1e-3
oAbsolute deviation of grid spacing: ≤ 1e-3
•Thermal expansion: ~ 24e-6/K
•Outer dimension tolerance: ±0.5mm
•Thickness tolerance: ±0.2mm
Note: Thermal expansion is provided for reference only and is usually irrelevant in practical applications.