StoreCalibration

Stores the active calibration data and workspace link into permanent EEPROM storage on the camera. This effectively writes the data of the Link and Calibration nodes into the camera eeprom.

Error Symbols

EepromUpgradeNeeded

Cause: One of the cameras has an eeprom format that does not support storing the current camera state. This happens most likely because your software has a newer calibration format than the software the camera was calibrated with. The available calibration formats and the NxLib versions that support them are listed here.

Solution: If you are using the camera only with your current software release or newer releases, it is safe to upgrade the eeprom format by specifying the Force parameter and rerunning the command. If you need the camera to be compatible with older software releases you should calibrate the camera with this older release.