Blind

The blind ethernet configuration can be used to set up the ethernet configuration for X-series projectors and GigE Vision cameras that were not discovered in the camera list, because they don’t have a valid IP address yet.

When the blind ethernet configuration is active you need to specify the devices which you want to configure. For projectors, this is done by their serial in the Cameras parameter. For GigE Vision cameras, you need to specify their MAC addresses in the MacAddresses parameter. You cannot specify both types of devices at the same time.

The command will try to set the IP configuration of the specified devices by sending broadcast messages on all available adapters.

Format

Boolean

Whether to perform a blind ethernet configuration for projectors or GigE Vision cameras that have not been discovered yet.

Default

false