Open

Opens one or more cameras such that they can be used in this NxLib instance.

Error Symbols

errInvalidCalibrationData

Cause:

The camera’s calibration data is either corrupted or not recognized by the current software version.

Solutions:

  1. If you are using a current software revision but your calibration data is corrupted you can use NxView’s calibration dialog to download and restore the factory calibration data to the camera eeprom.

  2. If you want to open a newly purchased camera with an older software revision, the camera’s calibration data format might not be recognized by your software. You can then download the pattern data of the factory calibration via the NxView calibration dialog and recompute the calibration data in the older format compatible with your software revision.

errWiringTestFailed

Cause:

The wiring between the projector and the cameras of an X-series camera.

Solution:

Check whether the cameras are swapped and make sure that the trigger cables are connected to the cameras.